Beli elcb abb di monotaro.id
Kami Menampilkan Rekomendasi Kami Untuk Anda! Anda Bisa Membelinya Kapan Saja di monotaro.id
- ABB Arc Fault Detection Device Integrated with RCBODeskripsi:DS-ARC1 C6 A30 Arc fault detection device integrated with RCBODS-ARC1 is a 1P+N arc fault detection device (AFDD) with an integrated RCBO in three modules, for the protection against earth arc faults, parallel arc faults, series arc faults, overvolatge, short-circuit currents, overload, earth fault currentsatribut:
- Connecting Capacity (mm²): Busbar 10, Rigid 1-25, Flexible 1-25
- Built-in Depth (mm): 69
- Auxiliary Voltage AC/DC (V): 230
- Accessory Type: Auxiliary contact, Signal contact / auxiliary contact, Shunt trip, Undervoltage release, Overvoltage release, Auxiliary contact for bottom fitting
- Actuator Type: Toggle - Insulation group II, Orange RAL 2004, sealable in ON-OFF-positions
- Cable Size (mm²): 25
- Contact Position Indication: Red ON / Green OFF
- Dielectric Test Voltage (kV): 2.5
- Electrical Endurance (cycle): 10000
- Energy Limiting Class: 3
- Fault Indication: Blue flag on toggle
- Frequency (Hz): 50
- Housing Type: Insulation group I, RAL 7035
- Leakage Current Type: A
- Mechanical Endurance (cycle): 20000
- Mounting Position: Any
- Mounting Position of Accessories: Right
- Number of Poles: 2
- Number of Protected Poles: 1
- Schneider Electric Residual Current Circuit Breaker Domae (RCCB/ELCB)atribut:
- Control Type: Toggle
- Earth-Leakage Protection Class: Type AC
- Network Frequency (Hz): 50
- ABB Residual Current Circuit Breakers with Overcurrent ProtectionDeskripsi:DS201 L C6 AC30 Residual Current Circuit Breaker with Overcurrent ProtectionThe DS201 series is a 1P+N RCBO in two-modules width for the protection of end user single-phase circuits against overload and short-circuit currents; protection against the effects of sinusoidal alternating earth fault currents; protection against indirect contacts and additional protection against direct contacts (with sensitivity = 30 mA).
- ABB Current TransformerDeskripsi:CT PRO XT 40 Current transformerCT PRO XT 40 is used to transform primary currents to../5A secondary currents for c.a. measurement instrumentsatribut:
- Current Limit Function: FS 5
- Frequency (Hz): 50-60
- Chint Arc Fault Detection Circuit Breaker Integrated with RCBO (AFDD)atribut:
- Breaking Capacity (kA): 6
- Sensivity Current (mA): 30
- Frequency (Hz): 50
- Compliant standard: IEC61009-1; IEC62606
- Tripping Curve: C
- Schneider Electric RCBO Slim Domaeatribut:
- Number of Poles: 2P
- Earth-Leakage Sensitivity (mA): 30
- Breaking Capacity (kA): 6
- Rated Operational Voltage (V): 230 (AC)
- Frequency (Hz): 50/60
- Curve Code: C
- Magnetic Trip: 5-10xIn
- Trip Unit: Thermal-magnetic
- ABB Arc Fault Detection Device Integrated with MCBDeskripsi:S-ARC1 C6 Arc fault detection device integrated with MCBS-ARC1 is a 1P+N arc fault detection device (AFDD) with an integrated MCB in two modules, for the protection against short-circuit currents, overload, earth arc faults, parallel arc faults and series arc faults.atribut:
- Built-in Depth (mm): 69
- Auxiliary Voltage AC/DC (V): 230
- Accessory Type: Auxiliary contact, Signal contact / auxiliary contact, Shunt trip, Undervoltage release, Overvoltage release
- Actuator Type: Toggle - Insulation group II, Orange RAL 2004, sealable in ON-OFF-positions
- Cable Size (mm²): 25
- Contact Position Indication: Red ON / Green OFF
- Dielectric Test Voltage (kV): 2.5
- Electrical Endurance (cycle): 10000
- Energy Limiting Class: 3
- Housing Type: Insulation group I, RAL 7035
- Input Voltage Type: AC
- Mechanical Endurance (cycle): 20000
- Mounting Position: Any
- Mounting Position of Accessories: Right
- Number of Poles: 2
- Number of Protected Poles: 1
- Overvoltage Category: III
- Chint Residual Current Circuit Breaker with Overcurrent Protection (RCBO)atribut:
- Breaking Capacity (kA): 6
- Frequency (Hz): 50/60
- Tripping Curve: C
- Compliant standard: IEC61009-1
- Hager Combined MCB/RCD (RCBO)Deskripsi:Compact protection devices which provide MCB overcurrent protection and RCCB earth leakage protection in a single unit. Specification IEC 61009-1 Protected against transient voltages (lightning, line disturbances,..) and transient currents (from high capacitive circuits) Technical data : The units are available with current ratings of 6A, 10A, 16A, 20A, 25A, 32A and 40A. The device switches both the phase and neutral conductors. All ratings have 10mA, 30mA, 100mA or 300mA earth leakage protection. The units feature indicators which show whether tripping is due to an overcurrent or earth leakage fault. Mechanical life : -2.000 operations -6kA IEC 61 009-1 -10kA IEC 60 947-2 Connection capacity -Rigid conductor 25mm2 -Flexible conductor 16mm2atribut:
- Number of Poles: 2
- Breaking Capacity (kA): 6
- Voltage Rating (V): 127-230
- Current Rating (A): 6-40
- LS Electric Residual Current Circuit Breaker with Overload (RCBO) 1P+NDeskripsi:- Proteksi Arus Bocor dengan Proteksi beban lebih - 30mA untuk proteksi terhadap manusia - 100mA & 300mA untuk proteksi terhadap bahaya kebakaran - Cocok digunakan di rumah, apartemen & lokasi-lokasi yang lembab - Kapasitas pemutusan 4.5kA (RKP) pada 230VAC 2.5kA (KGRd & GRHd) 1.5kA (KGRc & GRHc) 110/220 VAC - Kurva C - Standar IEC 61009atribut:
- Type: RKP
- Number of Poles: 1P + Neutral
- Legrand RCBO - DX3 6000 4 Modulesatribut:
- Breaker Type: AC
- Schneider Electric Domae MCB Miniature Circuit Breaker 3Patribut:
- Number of Poles: 3P
- Breaking Capacity (kA): 6
- Rated Operational Voltage (V): 400 (AC)
- Curve Code: C
- Frequency (Hz): 50/60
- Magnetic Trip: 5-10xIn
- Trip Unit: Thermal-magnetic
- ABB Miniature Circuit Breakers 2PDeskripsi:System Pro M Compact S200M Miniature Circuit Breakers Are Current Limiting. They Have Two Different Tripping Mechanisms, The Delayed Thermal Tripping Mechanism For Overload Protection And The Electromechanic Tripping Mechanism For Short Circuit Protection. They Are Available In Different Characteristics (B,C,D,K,Z), Configurations (1P,1P+N,2P,3P,3P+N,4P), Breaking Capacities (Up To 10 Ka At 230/400 V Ac) And Rated Currents (Up To 63A). All Mcbs Of The Product Range S200M Comply With Iec/En 60898-1 And Iec/En 609 47-2, Allowing The Use For Residential, Commercial And Industrial Applications. Bottom-Fitting Auxiliary Contact Can Be Mounted On S200M To Save 50% Space.atribut:
- Number of Poles: 2
- ABB Under Voltage Release for MCB, RCD, RCBoatribut:
- Number of Contacts CO: 0
- Number of Contacts NC: 0
- Number of Contacts NO: 0
- Number of switches: 1
- Product Height (mm): 85
- Product Length (mm): 74
- Product Width (mm): 18
- Suitable for Product Class: Miniature Circuit Breakers MCBsResidual Current Devices RCDsResidual Current Breakers with Overload Protection RCBo
- Schneider Electric Domae MCB Miniature Circuit Breaker 1Patribut:
- Breaking Capacity (kA): 6
- Curve Code: C
- Rated Operational Voltage (V): 230
- Number of Poles: 1P
- Frequency (Hz): 50/60
- Magnetic Trip: 5~10 x In
- Mounting Mode: Clip-on
- Network Type: AC
- Trip Unit: Thermal-magnetic
- GAE Current Transformer Rectangular Type (CT)Deskripsi:A completely enclosed of current transformer most appropriate for use in low voltage switchboard plats and key components in measurement system.atribut:
- Case Color: Black
- Class: CL 1.0
- Case Material: PC V0
- Class of Insulation: E
- FS Size: 10
- Highest Voltage For Equipment Um (r.m.s.) (kV): 0.72
- Rated Dynamic Current (idyn) (lth): 2.5
- Rated Frequency (Hz): 50-60
- Rated Power-frequency Withstand Voltage (r.m.s.) (kV): 3
- Rated Short-time Thermal Current (ith) (lpn): 60
- Relative Humidity: 95% (Non Condensing)
- Storage Temperature (°C): -10 to +70
- Working Temperature (°C): 0 to 50
- Schneider Electric Acti iID RCCBatribut:
- Product or Component Type: Residual Current Circuit Breaker (RCCB)
- Device Location in System: Outgoer
- Device Short Name: IID
- Product Name: Acti 9 iID
- Range: Acti 9
Daftar Harga elcb abb Terbaru January 2026
| ABB Arc Fault Detection Device Integrated with RCBO | Rp4.099.900 |
| Schneider Electric Residual Current Circuit Breaker Domae (RCCB/ELCB) | Rp489.900 |
| ABB Residual Current Circuit Breakers with Overcurrent Protection | Rp589.900 |
| ABB Current Transformer | Rp329.900 |
| Chint Arc Fault Detection Circuit Breaker Integrated with RCBO (AFDD) | Rp3.099.900 |
| Schneider Electric RCBO Slim Domae | Rp539.900 |
| ABB Arc Fault Detection Device Integrated with MCB | Rp2.799.900 |
| Chint Residual Current Circuit Breaker with Overcurrent Protection (RCBO) | Rp159.900 |
| Hager Combined MCB/RCD (RCBO) | Rp1.499.900 |
| LS Electric Residual Current Circuit Breaker with Overload (RCBO) 1P+N | Rp299.900 |
Data diperbarui pada 20/01/2026 (Harga belum termasuk PPN)




















































































































































/g7P103101583-5.jpg)


/f8P109164548-1.jpg)


/b8P109165404-1.jpg)
/8qP103455314-1.jpg)
%201P%2BN/q4P103960940-1.jpg)







/llP108909777-1.jpg)

