Beli elcb abb di monotaro.id
Kami Menampilkan Rekomendasi Kami Untuk Anda! Anda Bisa Membelinya Kapan Saja di monotaro.id
- ABB Arc Fault Detection Device Integrated with RCBODeskripsi:DS-ARC1 C6 A30 Arc fault detection device integrated with RCBODS-ARC1 is a 1P+N arc fault detection device (AFDD) with an integrated RCBO in three modules, for the protection against earth arc faults, parallel arc faults, series arc faults, overvolatge, short-circuit currents, overload, earth fault currentsatribut:
- Connecting Capacity (mm²): Busbar 10, Rigid 1-25, Flexible 1-25
- Built-in Depth (mm): 69
- Auxiliary Voltage AC/DC (V): 230
- Accessory Type: Auxiliary contact, Signal contact / auxiliary contact, Shunt trip, Undervoltage release, Overvoltage release, Auxiliary contact for bottom fitting
- Actuator Type: Toggle - Insulation group II, Orange RAL 2004, sealable in ON-OFF-positions
- Cable Size (mm²): 25
- Contact Position Indication: Red ON / Green OFF
- Dielectric Test Voltage (kV): 2.5
- Electrical Endurance (cycle): 10000
- Energy Limiting Class: 3
- Fault Indication: Blue flag on toggle
- Frequency (Hz): 50
- Housing Type: Insulation group I, RAL 7035
- Leakage Current Type: A
- Mechanical Endurance (cycle): 20000
- Mounting Position: Any
- Mounting Position of Accessories: Right
- Number of Poles: 2
- Number of Protected Poles: 1
- ABB Residual Current Circuit Breakers with Overcurrent ProtectionDeskripsi:DS201 L C6 AC30 Residual Current Circuit Breaker with Overcurrent ProtectionThe DS201 series is a 1P+N RCBO in two-modules width for the protection of end user single-phase circuits against overload and short-circuit currents; protection against the effects of sinusoidal alternating earth fault currents; protection against indirect contacts and additional protection against direct contacts (with sensitivity = 30 mA).
- ABB Arc Fault Detection Device Integrated with MCBDeskripsi:S-ARC1 C6 Arc fault detection device integrated with MCBS-ARC1 is a 1P+N arc fault detection device (AFDD) with an integrated MCB in two modules, for the protection against short-circuit currents, overload, earth arc faults, parallel arc faults and series arc faults.atribut:
- Built-in Depth (mm): 69
- Auxiliary Voltage AC/DC (V): 230
- Accessory Type: Auxiliary contact, Signal contact / auxiliary contact, Shunt trip, Undervoltage release, Overvoltage release
- Actuator Type: Toggle - Insulation group II, Orange RAL 2004, sealable in ON-OFF-positions
- Cable Size (mm²): 25
- Contact Position Indication: Red ON / Green OFF
- Dielectric Test Voltage (kV): 2.5
- Electrical Endurance (cycle): 10000
- Energy Limiting Class: 3
- Housing Type: Insulation group I, RAL 7035
- Input Voltage Type: AC
- Mechanical Endurance (cycle): 20000
- Mounting Position: Any
- Mounting Position of Accessories: Right
- Number of Poles: 2
- Number of Protected Poles: 1
- Overvoltage Category: III
- Hager Combined MCB/RCD (RCBO)Deskripsi:Compact protection devices which provide MCB overcurrent protection and RCCB earth leakage protection in a single unit. Specification IEC 61009-1 Protected against transient voltages (lightning, line disturbances,..) and transient currents (from high capacitive circuits) Technical data : The units are available with current ratings of 6A, 10A, 16A, 20A, 25A, 32A and 40A. The device switches both the phase and neutral conductors. All ratings have 10mA, 30mA, 100mA or 300mA earth leakage protection. The units feature indicators which show whether tripping is due to an overcurrent or earth leakage fault. Mechanical life : -2.000 operations -6kA IEC 61 009-1 -10kA IEC 60 947-2 Connection capacity -Rigid conductor 25mm2 -Flexible conductor 16mm2atribut:
- Number of Poles: 2
- Breaking Capacity (kA): 6
- Voltage Rating (V): 127-230
- Current Rating (A): 6-40
- Legrand RCBO - DX3 6000 Type N Right Handatribut:
- Rated Voltage (V): 230
- Frequency (Hz): 50
- Number of Pole: 2 (total)
- IP Protection: IP20
- Built-in Depth (mm): 44
- Connectable Conductor Cross Section Solid Core (mm²): 0.75-16
- Flush-mounted Installation: Yes
- Number of Protected Poles: 1
- Pollution Degree: 2
- Width in Number of Modular Spacings: 2
- Legrand RCBO - DX3 6000 4 Modulesatribut:
- Breaker Type: AC
- LS Electric Residual Current Circuit Breaker with Overload (RCBO) 1P+NDeskripsi:- Proteksi Arus Bocor dengan Proteksi beban lebih - 30mA untuk proteksi terhadap manusia - 100mA & 300mA untuk proteksi terhadap bahaya kebakaran - Cocok digunakan di rumah, apartemen & lokasi-lokasi yang lembab - Kapasitas pemutusan 4.5kA (RKP) pada 230VAC 2.5kA (KGRd & GRHd) 1.5kA (KGRc & GRHc) 110/220 VAC - Kurva C - Standar IEC 61009atribut:
- Type: RKP
- Number of Poles: 1P + Neutral
- ABB Under Voltage Release for MCB, RCD, RCBoatribut:
- Number of Contacts CO: 0
- Number of Contacts NC: 0
- Number of Contacts NO: 0
- Number of switches: 1
- Product Height (mm): 85
- Product Length (mm): 74
- Product Width (mm): 18
- Suitable for Product Class: Miniature Circuit Breakers MCBsResidual Current Devices RCDsResidual Current Breakers with Overload Protection RCBo
- Legrand RCD RX3atribut:
- Impact Protection (IK): IK04
- Color: Grey
- IP Protection: IP20
- Rated Voltage (V): 230
- Number of Pole: 2
- Built-in Depth (mm): 44
- Depth (mm): 77.8
- Frequency (Hz): 50
- Halogen Free: Yes
- Height (mm): 88.9
- Mounting Method: DIN rail
- Nominal Voltage (V): 180-250
- Storage Temperature (°C): -40-70
- Voltage Type: AC
- Width (mm): 35.6
- Schneider Electric TeSys Deca Electronic Relaysatribut:
- Separate Part Category: Connection accessory
- Device Short Name: LAD
- ABB Miniature Circuit Breakers 2PDeskripsi:System Pro M Compact S200M Miniature Circuit Breakers Are Current Limiting. They Have Two Different Tripping Mechanisms, The Delayed Thermal Tripping Mechanism For Overload Protection And The Electromechanic Tripping Mechanism For Short Circuit Protection. They Are Available In Different Characteristics (B,C,D,K,Z), Configurations (1P,1P+N,2P,3P,3P+N,4P), Breaking Capacities (Up To 10 Ka At 230/400 V Ac) And Rated Currents (Up To 63A). All Mcbs Of The Product Range S200M Comply With Iec/En 60898-1 And Iec/En 609 47-2, Allowing The Use For Residential, Commercial And Industrial Applications. Bottom-Fitting Auxiliary Contact Can Be Mounted On S200M To Save 50% Space.atribut:
- Number of Poles: 2
- Chint Residual Current Circuit Breaker with Overcurrent Protection (RCBO)atribut:
- Breaking Capacity (kA): 6
- Frequency (Hz): 50/60
- Tripping Curve: C
- Compliant standard: IEC61009-1
- Pelican Flashlight LED LanternDeskripsi:Less than 3lbs + 2207 lumens = brightest & lightest in its classAt less than 3 pounds and 2207 lumens, the new 9410L LED Lantern packs the power without the weight. Four LEDs, powered by the latest generation Lithium-Ion batteries illuminate a distance of 495 yards (453 meters). And it's loaded with innovative technology and features you have come to expect from Pelican. The 9410L LED Lantern is one of the most compact, high output lanterns on the market.atribut:
- Body Material: ABS
- Shroud Material: EXL
- Lens Material: Polycarbonate (PC)
- O-Ring Materials: EPDM
- Legrand RCBO Arteoratribut:
- Color: White
- Rated Voltage (V): 230
- Rated Current (A): 16
- Frequency (Hz): 50/60
- IP Protection: IP20
- Impact Protection (IK): IK04
- Ambient Temperature During Operating (°C): -5-40
- Built-in Depth (mm): 44.5
- Connectable Conductor Cross Section Solid Core (mm²): 2.5-2.5
- Depth (mm): 44.5
- Halogen Free: Yes
- Height (mm): 44
- Label Space/Information Surface: No
- Mounting Method: Surface mounted/recessed mounted
- Nominal Voltage (V): 230-240
- Number of Pole: 1 (total)
- Number of Protected Poles: 1
- Storage Temperature (°C): -10-70
- Width (mm): 44
- Width in Number of Modular Spacings: 44
- Shihlin Electric RCBO 3Patribut:
- Number of Poles: 3P
- Leakage Current (mA): 30
Daftar Harga elcb abb Terbaru September 2025
ABB Arc Fault Detection Device Integrated with RCBO | Rp4.099.900 |
ABB Residual Current Circuit Breakers with Overcurrent Protection | Rp589.900 |
ABB Arc Fault Detection Device Integrated with MCB | Rp2.799.900 |
Hager Combined MCB/RCD (RCBO) | Rp1.299.900 |
Boss RCBO | Rp419.900 |
Legrand RCBO - DX3 6000 Type N Right Hand | Rp659.900 |
Legrand RCBO - DX3 6000 4 Modules | Rp1.899.900 |
LS Electric Residual Current Circuit Breaker with Overload (RCBO) 1P+N | Rp299.900 |
ABB Under Voltage Release for MCB, RCD, RCBo | Rp1.199.900 |
Legrand RCD RX3 | Rp439.900 |
Data diperbarui pada 07/09/2025 (Harga belum termasuk PPN)